Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cochrane Database Syst Rev ; 5: CD014715, 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38721874

RESUMO

BACKGROUND: Prenatal ultrasound is widely used to screen for structural anomalies before birth. While this is traditionally done in the second trimester, there is an increasing use of first-trimester ultrasound for early detection of lethal and certain severe structural anomalies. OBJECTIVES: To evaluate the diagnostic accuracy of ultrasound in detecting fetal structural anomalies before 14 and 24 weeks' gestation in low-risk and unselected pregnant women and to compare the current two main prenatal screening approaches: a single second-trimester scan (single-stage screening) and a first- and second-trimester scan combined (two-stage screening) in terms of anomaly detection before 24 weeks' gestation. SEARCH METHODS: We searched MEDLINE, EMBASE, Science Citation Index Expanded (Web of Science), Social Sciences Citation Index (Web of Science), Arts & Humanities Citation Index and Emerging Sources Citation Index (Web of Science) from 1 January 1997 to 22 July 2022. We limited our search to studies published after 1997 and excluded animal studies, reviews and case reports. No further restrictions were applied. We also screened reference lists and citing articles of each of the included studies. SELECTION CRITERIA: Studies were eligible if they included low-risk or unselected pregnant women undergoing a first- and/or second-trimester fetal anomaly scan, conducted at 11 to 14 or 18 to 24 weeks' gestation, respectively. The reference standard was detection of anomalies at birth or postmortem. DATA COLLECTION AND ANALYSIS: Two review authors independently undertook study selection, quality assessment (QUADAS-2), data extraction and evaluation of the certainty of evidence (GRADE approach). We used univariate random-effects logistic regression models for the meta-analysis of sensitivity and specificity. MAIN RESULTS: Eighty-seven studies covering 7,057,859 fetuses (including 25,202 with structural anomalies) were included. No study was deemed low risk across all QUADAS-2 domains. Main methodological concerns included risk of bias in the reference standard domain and risk of partial verification. Applicability concerns were common in studies evaluating first-trimester scans and two-stage screening in terms of patient selection due to frequent recruitment from single tertiary centres without exclusion of referrals. We reported ultrasound accuracy for fetal structural anomalies overall, by severity, affected organ system and for 46 specific anomalies. Detection rates varied widely across categories, with the highest estimates of sensitivity for thoracic and abdominal wall anomalies and the lowest for gastrointestinal anomalies across all tests. The summary sensitivity of a first-trimester scan was 37.5% for detection of structural anomalies overall (95% confidence interval (CI) 31.1 to 44.3; low-certainty evidence) and 91.3% for lethal anomalies (95% CI 83.9 to 95.5; moderate-certainty evidence), with an overall specificity of 99.9% (95% CI 99.9 to 100; low-certainty evidence). Two-stage screening had a combined sensitivity of 83.8% (95% CI 74.7 to 90.1; low-certainty evidence), while single-stage screening had a sensitivity of 50.5% (95% CI 38.5 to 62.4; very low-certainty evidence). The specificity of two-stage screening was 99.9% (95% CI 99.7 to 100; low-certainty evidence) and for single-stage screening, it was 99.8% (95% CI 99.2 to 100; moderate-certainty evidence). Indirect comparisons suggested superiority of two-stage screening across all analyses regarding sensitivity, with no significant difference in specificity. However, the certainty of the evidence is very low due to the absence of direct comparisons. AUTHORS' CONCLUSIONS: A first-trimester scan has the potential to detect lethal and certain severe anomalies with high accuracy before 14 weeks' gestation, despite its limited overall sensitivity. Conversely, two-stage screening shows high accuracy in detecting most fetal structural anomalies before 24 weeks' gestation with high sensitivity and specificity. In a hypothetical cohort of 100,000 fetuses, the first-trimester scan is expected to correctly identify 113 out of 124 fetuses with lethal anomalies (91.3%) and 665 out of 1776 fetuses with any anomaly (37.5%). However, 79 false-positive diagnoses are anticipated among 98,224 fetuses (0.08%). Two-stage screening is expected to correctly identify 1448 out of 1776 cases of structural anomalies overall (83.8%), with 118 false positives (0.1%). In contrast, single-stage screening is expected to correctly identify 896 out of 1776 cases before 24 weeks' gestation (50.5%), with 205 false-positive diagnoses (0.2%). This represents a difference of 592 fewer correct identifications and 88 more false positives compared to two-stage screening. However, it is crucial to acknowledge the uncertainty surrounding the additional benefits of two-stage versus single-stage screening, as there are no studies directly comparing them. Moreover, the evidence supporting the accuracy of first-trimester ultrasound and two-stage screening approaches primarily originates from studies conducted in single tertiary care facilities, which restricts the generalisability of the results of this meta-analysis to the broader population.


Assuntos
Primeiro Trimestre da Gravidez , Segundo Trimestre da Gravidez , Ultrassonografia Pré-Natal , Humanos , Feminino , Gravidez , Ultrassonografia Pré-Natal/estatística & dados numéricos , Sensibilidade e Especificidade , Viés , Anormalidades Congênitas/diagnóstico por imagem
2.
Laryngoscope ; 2024 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-38676421

RESUMO

OBJECTIVES: Down syndrome (DS) is associated with airway abnormalities including a narrowed trachea. It is uncertain whether this narrowed trachea in DS is a consequence of deviant fetal development or an acquired disorder following endotracheal intubation after birth. This study aimed to compare the tracheal morphology in DS and non-DS fetuses using microfocus computed tomography (micro-CT). METHODS: Twenty fetal samples were obtained from the Dutch Fetal Biobank and divided into groups based on gestational age. Micro-CT images were processed to analyze tracheal length, volume, and cross-sectional area (CSA). RESULTS: Mean tracheal length and tracheal volume were similar in DS and non-DS fetuses for all gestational age groups. Mean, minimum, and maximal tracheal CSA were statistically significantly increased in the single DS fetus in the group of 21-24 weeks of gestation, but not in other gestational age groups. In 90% of all studied fetuses, the minimum tracheal CSA was located in the middle third of the trachea. CONCLUSION: Tracheal development in DS fetuses was similar to non-DS fetuses between 13 and 21 weeks of gestation. This suggests that the narrowed tracheal diameter in DS children may occur later in fetal development or results from postnatal intubation trauma. The narrowest part of the trachea is in majority of DS and non-DS fetuses the middle third. LEVEL OF EVIDENCE: Level 3 Laryngoscope, 2024.

3.
Dev Cell ; 58(24): 2826-2835, 2023 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-38113849

RESUMO

Recent studies of human embryos and fetuses have advanced our understanding not only of basic biology but also of health and disease, through a combination of detailed three-dimensional (3D) morphology and processes such as gene expression, cellular decision-making and differentiation, and epigenetics during the various phases of human development and growth. Large-scale research initiatives focusing on these topics have been initiated during the last decade, all of which depend on biobanks that provide high-quality images of human embryonic and fetal morphology, as well as on high-quality collections of tissue samples that are obtained and stored appropriately. In this perspective, we describe our experience in establishing the Dutch Fetal Biobank to present the framework and workflow of the biobank, provide a brief discussion of the main legal and ethical aspects involved in establishing a pre-natal tissue bank, and present the preliminary data on the first 329 donated specimens.


Assuntos
Bancos de Espécimes Biológicos , Pesquisa Biomédica , Humanos , Epigenômica , Feto , Padrões de Referência
4.
Pediatr Radiol ; 53(4): 632-639, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36169668

RESUMO

Over the last few years, fetal postmortem microfocus computed tomography (micro-CT) imaging has increased in popularity for both diagnostic and research purposes. Micro-CT imaging could be a substitute for autopsy, particularly in very early gestation fetuses for whom autopsy can be technically challenging and is often unaccepted by parents. This article provides an overview of the latest research in fetal postmortem micro-CT imaging with a focus on diagnostic accuracy, endovascular staining approaches, placental studies and the reversibility of staining. It also discusses new methods that could prove helpful for micro-CT of larger fetuses. While more research is needed, contrast-enhanced micro-CT has the potential to become a suitable alternative to fetal autopsy. Further research using this novel imaging tool could yield wider applications, such as its practise in imaging rare museum specimens.


Assuntos
Feto , Placenta , Feminino , Gravidez , Humanos , Autopsia/métodos , Idade Gestacional , Placenta/diagnóstico por imagem , Feto/diagnóstico por imagem , Microtomografia por Raio-X/métodos , Imageamento por Ressonância Magnética/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...